City will update well number two

GLENWOOD CITY — The city council has decided to update one of its two wells and pump. To satisfactorily come into compliance with a “Notice of Noncompliance” issued by the Department of Natural Resources back in July, the council ordered an inspection of well number two to determine what action they could take.

The July notice listed fourteen deficiencies at that well house including the well casing was not at the depth as required, the basement of the building had several inches of standing, unsanitary water, and that the building masonry wall was cracked. Other items in the report included that electrical conduit entering the well was not properly sealed, the pump had not been pulled for service in years, the well house door did not open outward, the chemical feed system is not being used and the generator is not being exercised monthly or under full load.

Several months ago the council approved to have the pump pulled and the well inspected. After that was completed, the council would have information on how to proceed with either updating the facility or abandon it and construct a new facility.

At the Council regular monthly meeting Monday evening, December 21st the council heard from the City’s Public Works Director, Doug Doornink. He presented members of the council with a report from Municipal Well and Pump out of Waupun, Wisconsin.

The December 11th report indicated that they pulled the number two pump and inspected the pump and components and televised the well. Their report states that the “existing four inch column pipe is in poor condition and there is pitting and significant corrosion wear and should be replaced.” The report continued, “Both the submersible wire and motor are in poor condition and warrant replacing. The existing submersible pump is in working order. We have inspected the pump. There are definite signs of age and corrosion as you would expect.” They recommend replacing the pump.

The report stated that the pump base and discharge head is compliant in regards to elevation from pump house floor. “The head should be replaced due to corrosion and old welding. The well was venting through the wire conduit. A compliant well vent should be installed.”

On December 4th, they televised the well and noted the following: “The six inch casing liner installed in 1988 is in good condition. The liner extends down to the bottom of the original casing and shows no signs of breach or corrosion. The borehole is significant in depth (545 feet) for the amount pumped (230 gallons per minute). There is a significant amount of fill with twenty or more feet. This should be bailed prior to re-install of the permanent pump.”

The report noted: “There is currently what appears to be a pipe or shaft at the bottom of the well.”

During his presentation about the well, Doornink recommended that the city keep that well and install a new pump and do the upgrade work. The city had approved a $10,285 figure to pull the old pump and do the inspection. To install the new pump and finish the work was estimated at another $10,520 and the council approved this item.

But as Doornink noted, there is still the question about the building and the need to install new chemical treating equipment. He told the council that at present the pump was tested on a regular basis, but was only used during emergencies, saying that the will was used during the Glenhaven and Logghe fires.

One other item the city could do was to abandon the site and purchase a large generator to operate the City’s only other well. The generator would be used in case of a power outage. The cost of that size generator was estimated at close to $100,000. The city’s current backup generator does not have the capacity to run the other pump which pumps at the rate of 900 gallons per minute. But members of the council felt that the city needs two wells to insure that there is a back up in case one well has problems.

Doornink explained to the Council that if the second well is in use, it must be run on a regular basis so that the pumps alternate with each other. To do that all the chemical feed equipment that is now at well three, must be duplicated for well number two.

There is one other thing that needs to be checked before the well is upgraded and that is to determine if the wellhead is above the hundred year flood level and the Council asked Cedar Corporation to survey it and make a report.

But, repairing the pump and well is only a small part of the needed improvements. Along with the chemical treatment equipment, the well house needs improvement and updating. Doornink told the council that he estimated that cost could run well over $100,000. At the end of the discussion about the well and pump, Mayor John Larson said that it looks like we will demolish the building and build a new structure. Kevin Oium of Cedar explained that a new building could be a much smaller structure than what is on the present site. At one time there were two wells at that location and when the city constructed a new well at Hinman Park, back in the 1980s, the second well was abandoned.